Arc Furnace Transformers

Arc furnace transformers have distinctive specifications such as high current in low voltage side and special loading sequence. Thus, comprehension of high current behaviors such as Foucault currents, even distribution in parallel conductors

Bushing current transformers

Protection current transformers (PPX) Measuring current transformers Multi-core current transformers Current transformers with multi-terminal secondary

Protection current transformers (P, PX)
Measuring current transformers
Multi-core current transformers

Current transformers with multi-terminal secondary

Butterfly Valve – wafer type

• 100% assured for sealing and leakage
• Valves can be ¬xed to the transformer ange with 8 special bolts
• Indicate disc position
• Adequately protected against the corrosion

Butterfly Valve-DN80

• The aluminum casted valve is designed for mounting
• Between Flanges of the transformer tank and radiators.
• Resistant against 2 bar air pressure
• Resistant against 1bar 90 C 30 min transformer oil

C.T Terminal box

• Terminals up to 12
• Protection degree: IP65
• Terminal box body: Aluminum LM24
• Terminals: Polyamide 6.6
• Powder coat with polyester resin according to the ITQ-MP03-01 standard for air side
• Resistant against 1bar 90 C 30 min transformer oil

Cast Resin Distribution Transformers

Cast resin distribution transformers can be used in distribution network instead of oil transformers, because of their high safety conditions, distribution substations can be designed nearer to the places of the consumers.

Continuously Transposed Cables

• All specifications of enameled rectangular wire are controlled acc. to IEC 60317 and tests made acc. to IEC 60851
• The transposed cable is delivered on a wooden reel, uniformly distributed and tightened.

Cut-out fuse insulators

11 kV cut-out fuse insulator, 24 kV cut-out fuse insulator (creeping distance 340 and 380 mm)

11 kV cut-out fuse insulator
24 kV cut-out fuse insulator

(Creeping distance: 340 and 380 mm)

Dehydrating Breathers Material

Injected aluminum upper part Injected aluminum lower part Standard color Electrostatic powder coating Dehumidifier chambers are produced according to DIN 42567 standard

Top section: casted aluminum
Bottom section: casted aluminum
Standard painting: Electrostatic coating
Dehydrating Breathers are produced acc. to DIN 42567

Distribution transformers with on-load tap changer

Distribution transformers with on-load tap-changers ensure that the voltage in public and industrial distribution grids remains stable by balancing fluctuations in the medium voltage and dynamically reacting to supply and load changes in the low voltage.

Double Floor Substations

Technical Specifications:
• Up to 1000 KVA / 36KV
• Easy accessibility to components
• Optimum layout
• Corrosion proof

Earthing Transformer

The main duty of earthing transformers is to provide neutral point for delta side of the main transformer. Winding connection of these transformers are zigzag, also they could have a secondary winding to perform as auxiliary transformer in substations.